| Tag RFID Format |
125 Khz, em4102 compatible |
| Storage capacity |
8.000 transactions with ID reader, ID tag, date, time and minutes |
| Data transfer |
Contactless (trough induction), two-way |
| Batteries autonomy |
Minimum 60 days or 3.000 readings |
| Batteries recharge |
Contactless, trough induction, max 30 hours |
| Watch accuracy |
Max 10 sec/month (from 20 to 30°C)
Typical 1 min/year (at 25°C) |
| Display |
graphic 128 x 64 |
| key |
tactile, back lighted trough starting |
| Viewable elements on display |
time and data-assigned name-read tag's number-battery condition |
| Reading reporting |
Buzzer and blue led in the key |
| Operating environment |
0-50° without condensation |
| Mechanical |
strength fall 50 cm. on cement |
| RFIDock Features |
· Interface RS232/USB, cable DB9 200 cm.
· external power supply 12 Vdc.
· Base with modularity 1 - 2 - 4 - 8 sections
· 4 signal's led: power supply- RFIDat reader presence- battery in recharge- data transfer in
progress
· Options: Ethernet interface |
| RFICom function |
· Recordings download from RFIDat terminals
· Formulation of reader parameters: date and time, device's logical name, formulation of terminal
mode( continuous, with button or in master mode)
· Management nominatives assignment to terminal with validity's time put in a historical context
· Management logical name's assignment( typically the passage or the position) to every tag
· Management of file string of recordings download
· Possibility to consult effected recordings for every terminal in chronological order. |
|